How do I hide the electrical panel in my finished basement? 

Ideas to Cover Up an Electrical Panel in a Finished Basement
  1. Hang a Picture. The most obvious way to hide a panel is to hang something over it.
  2. Build a Bookshelf.
  3. Build a Wall Cabinet.
  4. Hide the Panel in Plain Sight.

How do you hide an electrical breaker box? Strategically placed artwork, framed message boards, or a weaving or tapestry are all viable options for covering up obtrusive electrical eyesores. HGTV suggests inserting child proof safety plugs into unused outlets before covering with artwork.

How can I hide my power panel? 

Check with you local building authorities to make sure you can conceal an electrical panel without violating any codes.
  1. Picture Frame Electrical Panel Cover.
  2. Rustic Wooden Sign Electrical Panel Cover.
  3. Woven Wall Hanging.
  4. Dropcloth Magnet Electric Panel Cover.
  5. Vintage Window.
  6. Foam Poster Board Electrical Panel Cover.
  7. 7 & 8.

Can you cover a breaker box with a picture? Circuit breaker boxes are often unpleasant to look at and costly to move. Fortunately, you can decorate over the box to blend it in with the rest of the room. For a quick fix, try hanging a painting or covered frame over it. A circuit breaker can also be hidden inside a cabinet as long as you keep it accessible.

Contents

Why Do Air Mattresses Make You Sweat?
READ

How do I hide the electrical panel in my finished basement? – Additional Questions

Can a breaker box be in a closet?

You cannot install an electrical panel in a clothes closet as per the National Electrical Code section 240.24D. The code standards state that electrical panels “cannot be close to flammable materials,” such as clothes.

How do you cover an electrical panel for cabinets?

Can an electrical panel be in a cabinet?

You cannot put it next to anything. There must a clear space in front of the panel for an electrician to stand. The space must be kept clear for at least 3 feet in front of the panel, and for 30 inches left to right in front of the panel.

Can you wallpaper over electrical panel?

Hang a picture over it if you must. Agreed, don’t wallpaper the box, it would be a code violation. You are not supposed to hang anything in front of it either, but it is pretty common to do that (and of course much easier to rectify if someone objects).

Does an electrical panel need a cover?

All electrical panels require a cover, called a dead front, to prevent touching any of the electrified (“live”) parts inside. The panel’s circuit breaker switches should stick through openings in the dead front, with all other openings closed.

Do breakers need to be covered?

National Electrical code does not require a door to cover breaker handles. It does require a cover that prevents access to electrified parts, which must have all openings closed. A panel without a door is not a violation, but a panel without a cover is.

What is a dead front cover?

Dead front covers have rectangular shaped slots that breakers fit into. If the cover has slots that are open but no breaker in it then pests may enter the panel, or children or others may inadvertently stick a metallic item in the open space.

How do you drywall around a breaker box?

Does electrical panel have to be flush with drywall?

When you install an electrical box, make sure it is flush with the surface of this drywall strip; this will ensure the boxes are at the proper depth when the walls are finished.

Do outlets go in before drywall?

Here’s a checklist of items that need to be installed before the drywall goes up: Electrical: All wiring and electrical boxes installed for wall outlets, switches, and light fixtures. Plumbing: Drain lines along with hot and cold water lines. Heating and Cooling: Any ductwork for room vents and air return.

Should outlet box be flush with drywall?

The front edge of the box must be flush with the finished wall surface, usually 1/2-inch-thick drywall.

Can I hide a junction box behind drywall?

Junction box covers must remain accessible; they cannot be covered with drywall or other surface material.

How high off the floor should outlets be?

As for typical heights, that isn’t as well-regulated (and we’re glad for that). Generally, you want to mount receptacle boxes with the bottom of the box about 16-inches off the floor. Coincidentally, this roughly equates to the same height as your garden variety 22-ounce framing hammer.

How far should electrical boxes stick out from the wall?

Electrical boxes should be mounted so that the outer edges are recessed no more than one-quarter inch (6 mm) from the drywall surface. The reason is not for aesthetics but to minimize the risk of arcing and electrical fires for safety.

How do you cover an electrical box with drywall?

As long as there are no wires inside the box, you can cover it with drywall. If the box is still acting as a junction box, however, and wires are joined inside it, the electrical code mandates a removable cover. Covers come in plastic or metal, and you attach them with machine screws.

What is a mud ring?

A mud ring on a electrical box is a cover with an opening for a switch or outlet and the edges protrude through the drywall or plaster to the outer surface of the wall.

Can I screw electrical box to a stud?

A better solution is to get a box similar to the one below with side screws already included to be mounted to the stud. This is the same size as the old work box but allows you to screw directly into the stud. Thanks JACK. That works too.

Can you screw through the side of an electrical box?

Screws shall not be permitted to pass through the box unless exposed threads in the box are protected using approved means to avoid abrasion of conductor insulation.

How do you secure an electrical box in the wall?

  1. Step 1: Trace Box. For your safety, turn off power before starting this project.
  2. Step 2: Cut Hole. Cut the hole with a drywall saw.
  3. Step 3: Thread Cables. Run cable through the hole.
  4. Step 4: Insert Box. Push the box into the hole.
  5. Step 5: Secure Box to Wall.
How To Remove Cord From Electric Blanket
READ

What screws to use for electrical box to stud?

For box mounting I use 2 #8 pan/ washer head screws. All the ones I have seen are Phillips or square drive #2, but there may be straight. Inspectors like the square head #2 because usually only electricians use these so it can help you pass inspection.

What screws do electricians use?

There are basically 3 types of anti tamper security screw that can be used to protect your electrical switches or 13 amp sockets; Raised Countersunk Security Torx screws (3.5mm) Raised Countersunk Security Hex screws (3.5mm) Raised Countersunk Security Two Hole screws (3.5mm)